BPE 40kVA/40kW GTP Series Online UPS 3‐Phase Input, 3‐Phase Output, Monolithic UPS Internal Battery

BPE
SKU:
GTP3340B40

Pricing available upon request

Current Stock:

True online double-conversion UPS with 3-level IGBT design, wide voltage/frequency range, high input/output power factor, low harmonic distortion (<3%), parallel up to 4 units, configurable batteries (16–50), transformer & IoT compatible.

Key Features

  • True Online Double Conversion Topology
  • 3-Level IGBT Based Rectifier & Inverter
  • Wide Input Voltage Range
  • High Input Power Factor : ≥ 0.99
  • Wide Input Frequency Range : 40-70Hz
  • Parallel upto 4 units
  • Static Bypass and Cold Start
  • High Output Power Factor : 0.9 & Configurable to 1.0
  • Low Harmonic Distortion : <3%
  • Configurable Batteries : 16~20 Nos. (For 10-30kVA) & 30~50 Nos. (For 30 & 40kVA)
  • Transformer Compatible
  • IOT Compatible

Technical Specifications

  • Capacity (kVA): 40
  • Input
    • Nominal Voltage: 380V / 400V / 415V AC (3Ph+N+PE)
    • Voltage Range: 208 - 478V AC
    • Frequency Range: 50 / 60 Hz ± 10% Auto Sensing
    • Power Factor: ≥ 0.99
    • Harmonic Distortion (THDi): ≤ 2%
    • Bypass Range:
      • Voltage:
        • 380 V AC Max. Voltage: +25% (Optional +10%, +15%, +20%) 400V AC Max. Voltage: +20%(Optional +10%, +15%)
        • 415V AC Max. Voltage: +15% (Optional +10%) Min. Voltage: -45% (Optional -20%, -30%)
      • Frequency: ± 10% (Configurable)
    • Generator Input: Support
  • Output
    • Output Voltage: 380V / 400V / 415V AC (3Ph+N+PE)
    • Voltage Regulation: ± 1%
    • Power Factor: 0.9 Standard / Unity Optional
    • Frequency: Auto Sensing 50 / 60 Hz ± 1~10% Sync Mode (Configurable), 50/60 Hz ± 0.1 Hz Battery Mode
    • Crest Factor: 3:1
    • Harmonic Distortion (THDv): ≤ 2%
    • Overload: ≤ 125% for 10 Min, ≤ 150% for 1 Min, ≥ 150% for 200 ms
    • Efficiency: 96.5% Dual Conversion Mode, 99.0% ECO Mode
  • Battery
    • Battery Voltage: 360 - 600 VDC
  • System Features
    • Transfer Time: Zero
    • Self-Diagnostics / EPO: Upon Power On and Software Control / Inbuilt
    • IP Protection: IP20
    • Alarm / Protection: Line Failure, Battery Low, Overload, System Fault and Short Circuit
    • Display:
      • LED: Line Mode, Bypass Mode, Battery Low, Overload and UPS Fault Codes
      • LCD: Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load %, Battery Voltage & Temperature, Output W/VA
    • Parallel: Inbuilt
  • Physical
    • Dimension, W x D x H (mm): 250x580x655
    • Net Weight (Kgs): 47
  • Environment
    • Temperature:
      • Operating: 0 ~ 50°C
      • Storage: -25ºC ~ 55ºC
    • Humidity / Altitude: 0~95% RH (Non-condensing) / 1500M
    • Noise: <60dBA
  • Standards
    • Quality: ISO 9001, ISO 14001, ISO 27001, ISO 45001, ISO 50001, RoHS
    • Safety: IEC/EN62040-1
    • EMC / Performance: IEC/EN62040-2; IEC/EN62040-3, Complying to CE
  • Communication Interface
    • Standard: RS232
    • Optional: SNMP / ModBus / Dry Contact / USB / RS485
    • Monitoring Software: NetAgent Utility v5.8 / View Power / UPSilon 2000 / Muser 4000