The PS32 series modular, online UPS ranging from 16kVA to 320kVA is designed to protect any critical load for medium and large data center achieving maximum availability. The PS32 series feature the latest technology of 3-level technology, PFC input control & Input Phase Sequence Correction, which guarantees ultra high efficiency of 96.8% and reliability.
Key Features
- Compact 320kVA in <1m² footprint
- High-density 16–32kVA modules (2U)
- 96.8% efficiency via 3-level IGBT
- Intelligent battery charging extends life
- Scalable up to 1920kVA (6 units parallel)
- 7” touchscreen with graphical interface
- Smart sleep mode saves energy at low load
- Supports RS232, RS485, USB, SNMP, AS400, dry contacts
- Compatible with lithium battery systems
Technical Specifications
- Module Rating: 20kVA
- Dimension WxDxH (mm): 440 × 620 × 86 (2U)
- Weight (Kg): 21
- Input
- Nominal Voltage: 380V / 400V / 415V AC (3Ph+N+PE)
- Operating Voltage Range: 228V - 480V AC Load Dependent
- Operating Frequency Range: 40Hz - 70Hz Auto Sensing
- Power Factor: ≥ 0.99
- Harmonic Distortion (THDi): ≤ 3%
- Generator Input / Walking: Support / 0-40 Sec. (Configurable)
- Output
- Output Voltage: 380V / 400V / 415V AC (3Ph+N+PE)
- Voltage Regulation: ± 1%
- Power Factor: 1.0 (Unity)
- Frequency: Auto Sensing 50 / 60 Hz ± 3Hz Sync Mode (Configurable), 50 / 60 Hz ± 0.1 Hz Battery Mode
- Crest Factor: 3:1
- Harmonic Distortion (THDv): ≤ 1%
- Over Load: ≤ 125% for 10 min, ≤ 150% for 1 min, > 150% for 200 ms
- Efficiency: 96.8% Dual Conversion Mode, 99% ECO Mode
- Battery
- Battery Voltage: ± 240V DC Nominal (30 ∼ 50 Nos. Configurable)
- System Feature
- Self-Diagnostics: During Power ON and Software Control
- EPO: UPS Shut down
- Transfer Time: Zero
- Alarm / Protections: Short Circuit, Input Under/Over Voltage, Over Temperature, Over Current,
Over Load, DC BUS Under/Over Voltage and Battery low
- Display: Touch Screen LCD & LED Indication
- Environmental
- Temperature:
- Operating: 0 ∼ 50°C*
- Storage: -15 ∼ 55°C
- Humidity / Altitude: 0-95% RH Non-condensing / <1500 M
- Noise: <55dBA
- Standards
- Quality: ISO 9001, ISO 14001, ISO 27001, ISO 50001, RoHS
- Safety: OHSAS 18001, IEC/EN62040-1
- EMC / Performance: Complying to CE, IEC/EN62040-2; IEC/EN62040-3
- Communication Interface
- Standard: Rack: RS-232, RS-485, Dry Contact
- Optional: BMS/ RS485/ LBS / SNMP / ModBus / Dry Contact / Parallel, Dry contact, Relay Card, Battery temperature sensor
- Monitoring Software: NetAgent Utility v5.8 / Muser 4000 / Power Manager