A DSP-controlled, true online double-conversion UPS with IGBT-based inverter and rectifier delivers pure sine wave output and high efficiency. It features low input harmonics (≤3%), high input/output power factors, and a wide input voltage and frequency range. The system supports configurable battery groups, ECO mode, self-testing, parallel operation (up to 4 units).
Key Features
- DSP Controlled True Online Double Conversion
- IGBT based both Inverter & Rectifier Technology
- Pure Sine Wave Output
- Input Current Harmonic ≤ 3%
- Optimization Battery Group (16/18/20 configurable)
- High Input Power Factor 0.99
- High Output Power Factor 1.0 (kVA = kW)
- Wide Input Voltage Range: 100V-300V AC
- Wide Input Frequency Range
- Support Economic Operation (ECO) Mode
- Self-Testing while UPS Startup
- Optional Parallel up to 4 units
- Support Common Battery Bank Operation
- In-built Static Bypass and Cold Start feature
- Auto Start and cold start function
- Generator Compatibility
Technical Specifications
- Capacity: 10 kVA
- Input
- Operating Voltage Range: 100V~300V AC Load Dependent
- Operating Frequency Range: 50 / 60 Hz ± 10% (Auto Sensing)
- Power Factor: ≥0.99
- Bypass
- Voltage: - 40% ~ +15% (Configurable)
- Frequency: ± 5% (Configurable)
- ECO Range: Same as the Bypass, can be configured
- Generator Input: Compatible
- Output
- Rated Voltage: 230V
- Power Factor: 1.0
- Voltage Regulation: ±1%
- Frequency: Auto Sensing 50 / 60 Hz ± 1~10% Sync Mode (Configurable), 50/60 Hz ± 0.5 Hz Battery Mode
- Crest Factor: 3:1
- Overload: ≤105% for Continuos, ≤ 125% for 10 Min, ≤ 150% for 60 Sec, ≥ 150% for 200ms
- Harmonic Distortion (THDv): ≤ 1%
- Efficiency: 94.0% Dual Conversion Mode, 99.0% ECO Mode
- Battery
- Battery Voltage: Inbuilt 16 Nos. of 12V/9Ah
- Typical Recharge Time: 4-5 Hours to 90% of full Capacity
- Charge Current: 10A (Configurable)
- System Features
- IP Protection: IP20
- Transfer Time: Zero
- EPO / ECO / CVCF: Shutdown UPS Immediately / ECO and CVCF Mode can be Configurable
- Alarm / Protection: Short Circuit, Input Under/Over Voltage, Over Temperature, Over Current, Over Load, DC BUS Under / Over Voltage and Battery low
- LED Display: Line Mode, Backup Mode, ECO Mode, Bypass Mode, Battery Low, Overload & UPS Fault
- LCD Display: Input Voltage, Input Frequency, Output Voltage, Frequency, Current; Load Percentage, Battery Voltage, Charging/ Discharging/Current Temperature & Remaining Battery Backup Time, Load VA/W, Load and Battery Barograph
- Environmental
- Temperature:
- Operating: 0~50°C*
- Storage: -15ºC ~ 60ºC
- Humidity / Altitude: 0~95% RH Non-condersing / <1500 M
- Noise: <55dBA
- Physical
- Dimension WxDxH (mm): 192 x 460 x 655
- Net Weight (Kg): 94
- Standards
- Quality: ISO 90001, ISO 14001, ISO 27001, ISO 45001, ISO 50001, BIS, RoHS, FCC
- Safety: IEC/EN62040-1; Conformity to IEC / EN
- EMC / Performance: IEC/EN62040-2; IEC/EN62040-3, Complying to CE, Compliance to UL
- Communication Interface
- Standard: RS-232
- Optional: SNMP / ModBus / Dry Contact / USB / RS-485 / SMS Alert Card
- Monitoring Software: BPE Cyber/ UPSilon 2000 / Muser 4000